Annexin V-PE Apoptosis Kit Plus

Catalog number
K203-25
Name
Annexin V-PE Apoptosis Kit Plus
Size
25 assays
Price
237.00 EUR
Supplier

Details

Kit's description
The Annexin V-PE Apoptosis Detection Kit Plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-PE Apoptosis Detection Kit Plus includes annexin V-PE, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeable to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-PE and SYTOX Green dye in the provided binding buffer, apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished by Fluorescence microscopy using FITC and PE filters or by flow cytometry using the FL1 channel (Ex. 488 nm/Em. 530 nm) for SYTOX Green dye and FL2 channel for Annexin V-PE (Ex. 488 nm/Em. 578 nm).
Highlights
• Detection method: Flow cytometry using FL1 channel for SYTOX Green dye (Ex = 488 nm; Em = 530 nm) and FL2 channel for Annexin V:PE (Ex = 488 nm; Em = 578 nm). • Species reactivity: Mammalian • Kit size: Convenient sizes (25, 100 and 400 assays) • Applications: Detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. PE shows brighter red fluorescence. Sytox green dye is also included to control necrosis.
Kit's benefits
• Simple one-step procedure; takes only 10 minutes • Fast and convenient • Apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence.
Category
Apoptosis Assay Kit
Kit's other name
none
Contents
• Annexin V-PE • SYTOX Green Dye • Binding Buffer
Storage condition
+4°C
Shipping condition
gel pack
Maximum time can be stored
12 months
Species reactivity
see datasheet
Applications
Detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. PE shows brighter red fluorescence. Sytox green dye is also included to control necrosis.
Samples tested
Live cells
Description
This Annexin V calcium dependent phospholipid binding protein will be downstream of BCL2 pathway and at caspase apoptotic level. Biovision has more cell death kits and antibodies.This 1 is suited for programmed cell-death studies.